Refrigeration Air Dryer PFD36-PFD240

PFD Refrigeration Air Dryer provides air quality in accordance with ISO8573.1 Class 4 for water vapor.

Contact Now

Product Parameters

Clean, Dry and Reliable Compressed Air

Moisture in the compressed air will causes major quality issues and expensive damages to the user such as premature wear and failure in pneumatic equipment, spoiled products and damaged control system. Having a clean, dry and reliable compressed air supply is essential to maintain efficient and low operating cost.

PSI provide completes compressed air treatment solutions with end user in mind. PFD refrigeration dryer is designed to remove water vapour from the compressed air by cooling through a highly efficient refrigerant circuit. PFD provides air quality in accordance with ISO8573.1 Class 4 for water vapour.


Features

  1. Easy Installation & Maintenance

  2. Simple and User Friendly Control

  3. Reliable Operation

  4. Environmentally Friendly Refrigerant

  5. Electronic Display Board

Product selection

 

ModelAir Flow Rate
Air ConnectionPower SupplyRefrigerant TypeDimmensions (mm)Weight(kg)
NM³/MinLWH
PFD36-PD0.6Rc 1/2"230V/1Ph/50HzR134a50025050025
PFD54-PD0.9Rc 1/2"230V/1Ph/50HzR134a50025050025
PFD72-PD1.2Rc 1/2"230V/1Ph/50HzR134a60031050030
PFD90-PD1.5Rc 1/2"230V/1Ph/50HzR134a60031050030
PFD108-PD1.8Rc 1/2"230V/1Ph/50HzR134a60031050030
PFD144-PD2.4Rc 3/4"230V/1Ph/50HzR134a75036055050
PFD180-PD3.0 Rc 3/4"230V/1Ph/50HzR134a75036055050
PFD216-PD3.6Rc 3/4"230V/1Ph/50HzR134a75036055055
PFD240-PD4.0 Rc 3/4"230V/1Ph/50HzR134a75036055055

Norminal dryer flow rated at inlet pressure 7 barg, inlet air temperature 42℃,ambient temperature 38℃ and dew point 3℃ to 10℃.

Technique info

How to select a suitable PSI Refrigeration Air Dryer

Correction factor for pressure barg (CP)

3456789101112131415
0.74 0.83 0.90 0.93 1.00 1.04 1.08 1.11 1.15 1.18 1.22 1.25 1.28 


Correction factor for inlet air temperature (CT)


35℃38℃40℃42℃45℃50℃55℃60℃
1.20 1.11 1.05 1.00 0.93 0.84 0.76 0.70 


Correction factor for ambient temperature (CA)


25℃30℃35℃38℃40℃45℃50℃
1.15 1.10 1.02 1.00 0.890.790.69



  1. Selected the correction factor(CP),(CT) and (CA).

  2. Calculate the dryer capacity require using the following: Actual flow rate=Nominal flow rate x CP x CT x CA

dryer 04.png